Journal of bronchology & interventional pulmonology
July 1, 2026
1 min readIP Score 10/10
The Effectiveness and Safety of Robotic-Assisted Bronchoscopy Across Diverse Patient Heights: A Subset Analysis of a Multicenter, Prospective, Observational Trial.
Gomes C; Cowan B; Benz H; Morris P; Pederson D; Schwiers M
Abstract
BACKGROUND: Outcomes of robotic-assisted bronchoscopy (RAB) in patients of small stature remain uncertain due to concerns about their potentially smaller lung volumes. We assess the effectiveness and safety of RAB across height variations. METHODS: This is a subset analysis of TARGET, a multicenter, prospective, observational study using the MONARCH Robotic Bronchoscopy Platform, which enrolled patients with lung lesions undergoing RAB across 21 sites. RAB safety and effectiveness were compared across height quartiles by assessing reach, measured through radial endobronchial ultrasound (r-EBUS) confirmation and the distance from the bronchoscope tip to the lesion, and access, evaluated by the diagnostic yield (DY). Comparisons across groups were performed via ANOVA, the Kruskal-Wallis test, or Fisher exact test as appropriate. RESULTS: A total of 679 patients were analyzed, categorized into height quartiles: 175.27 cm (N=168). Mean nodule size was 20.9 mm, with a distance from the pleura of 15.7 mm; 47.2% were in the outer third of the lung, with no significant differences across quartiles. r-EBUS localization succeeded in 91.7% of cases, with no quartile differences (P=0.95). The mean distance from the bronchoscope tip to the lesion was 22.6 mm, consistent across groups (P=0.84). Intermediate DY was higher in the third quartile of height, but no significant differences were observed for strict or liberal DY. Pneumothorax and bleeding rates were 4.1% and 2.4%, respectively, with no significant differences across quartiles (P=0.33 and 0.93, respectively). CONCLUSION: Our findings demonstrate a comparable effectiveness and safety profile of RAB across varying heights.
This case highlights the diagnostic and management challenges of refractory multisystem sarcoidosis progressing over a two-year period despite advanced biologic therapy.
Clinicians should note that the presence of targetable mutations in non-small cell lung cancer with malignant pleural disease is not associated with improved survival, based on the findings from this study.
Shape-sensing robotic-assisted bronchoscopy achieved a strict diagnostic yield of 70.2% with a low pneumothorax rate of 3.3%, demonstrating that earlier tissue diagnosis of very small pulmonary nodules is feasible and safe for clinical practice.
Up nextJournal of Thoracic DiseaseOct 30, 2026Read
This study introduces ultrasound-guided trans-cannula cryobiopsy of supraclavicular lymph nodes as a novel superficial lymph node approach for tissue acquisition in 10 consecutive patients, though specific numeric success or safety results were not provided in the abstract.
Active infection is not an absolute contraindication to endobronchial valve placement, but positive pressure ventilation significantly increases clinical failure odds with an aOR of 3.00 at P < 0.001.