INTRODUCTION: Multiple pulmonary nodules (MPNs) are commonly encountered in patients at elevated risk for thoracic malignancy and represent a spectrum of disease states and stages. We evaluated the safety, and procedural outcomes of a combined robotic assisted bronchoscopy (RaB) and linear endobronchial ultrasound (EBUS) approach to patients with MPNs during a single bronchoscopic procedure. METHODS: This multicenter observational registry included patients who underwent RaB for evaluation of MPNs. Data were prospectively collected from six centers between 2019 and 2025. Demographics, imaging characteristics, safety events, and procedural outcomes were analyzed and associated with final diagnosis. RESULTS: A total of 191 patients underwent RaB with biopsy of MPN during a single procedure; 167 patients also underwent linear EBUS lymph node sampling. The strict per nodule diagnostic yield was 71.5% overall (first nodule 70.7%, second 74.3%, third 71.4%). At least one malignant nodule was identified in 127 patients (66.8%), and 85 patients (44.5%) had two or more malignant nodules; 15 patients (17.6%) demonstrated heterogeneous histopathology between malignant nodules. Among patients with non-small cell lung cancer, adequate cellularity for next generation sequencing was achieved in 82.6% of nodules. Malignant lymph nodes were identified in 10.8% (18/167). No patients with two pure ground glass nodules (0/8) had malignant nodal involvement. Pneumothorax occurred in 7.3% of cases, with 2.1% requiring chest tube placement; unplanned admissions occurred in 3.7%. CONCLUSION: This study provides a large multisite registry evaluation of performance of simultaneous bronchoscopic sampling of multiple pulmonary nodules with EBUS staging during a single anesthesia event demonstrating an acceptable safety profile and adequacy for molecular profiling.
This case highlights the diagnostic and management challenges of refractory multisystem sarcoidosis progressing over a two-year period despite advanced biologic therapy.
Clinicians should note that the presence of targetable mutations in non-small cell lung cancer with malignant pleural disease is not associated with improved survival, based on the findings from this study.
Shape-sensing robotic-assisted bronchoscopy achieved a strict diagnostic yield of 70.2% with a low pneumothorax rate of 3.3%, demonstrating that earlier tissue diagnosis of very small pulmonary nodules is feasible and safe for clinical practice.
Up nextJournal of Thoracic DiseaseOct 30, 2026Read
This study introduces ultrasound-guided trans-cannula cryobiopsy of supraclavicular lymph nodes as a novel superficial lymph node approach for tissue acquisition in 10 consecutive patients, though specific numeric success or safety results were not provided in the abstract.
Active infection is not an absolute contraindication to endobronchial valve placement, but positive pressure ventilation significantly increases clinical failure odds with an aOR of 3.00 at P < 0.001.