Respiration_Online
November 30, 2023
1 min readIP Score 10/10
Performance of Biopsy Tools in Procurement of Lung Tissue in Robot-Assisted Peripheral Navigation: A Comparison
Abstract
AbstractIntroduction: Robot-assisted navigation bronchoscopy (RANB) has been gaining traction as a new technology for minimally invasive biopsies of peripheral pulmonary lesions (PPLs). Cryobiopsy is an established method of procuring satisfactory lung tissues and can be safely paired with RANB. While some studies have evaluated the diagnostic accuracy and yield of this procedure, there is limited data on the utility of various biopsy tools, the sequence of use and differences in tissue characteristics based on the sampling techniques. Therefore, this study aims to examine the real-life performance of needle, forceps and cryoprobe when utilized in succession with RANB in the biopsy of PPLs, and to evaluate the specific types of tissue samples obtained from each instrument. Methods: In a single-center retrospective study, 50 patients presenting 52 PPLs underwent biopsies sequentially using fine-needle aspiration (FNA), forceps, and cryoprobe. All procedures were performed via cone-beam CT-assisted RANB. Performance metrics, such as diagnostic yield, sensitivity, and specificity, were determined by classifying malignancy as true positives and explicit benign findings as true negatives. Tissue sizes and subtypes were based on pathology description and compared with Student’s t test and χ2, respectively. Results: Cryobiopsy, when performed sequentially after FNA then forceps, was able to retrieve more alveolar tissue (p = 0.0098) among diagnosed lesions and showed higher diagnostic yield (p = 0.001) in PPL biopsy with RANB platform. Cryobiopsy was also able to obtain larger sample size (p = 0.0087). No difference was observed in the diagnosis of malignancy between forceps and cryobiopsy (p = 0.8877). Conclusion: The integration of RANB and sequential biopsies, utilizing FNA, forceps, and cryoprobe, can efficiently diagnose PPLs and procure alveolar tissues. Further research based on histopathological subtypes is required to assess its prognostic significance.
This case highlights the diagnostic and management challenges of refractory multisystem sarcoidosis progressing over a two-year period despite advanced biologic therapy.
Clinicians should note that the presence of targetable mutations in non-small cell lung cancer with malignant pleural disease is not associated with improved survival, based on the findings from this study.
Shape-sensing robotic-assisted bronchoscopy achieved a strict diagnostic yield of 70.2% with a low pneumothorax rate of 3.3%, demonstrating that earlier tissue diagnosis of very small pulmonary nodules is feasible and safe for clinical practice.
Up nextJournal of Thoracic DiseaseOct 30, 2026Read
This study introduces ultrasound-guided trans-cannula cryobiopsy of supraclavicular lymph nodes as a novel superficial lymph node approach for tissue acquisition in 10 consecutive patients, though specific numeric success or safety results were not provided in the abstract.
Active infection is not an absolute contraindication to endobronchial valve placement, but positive pressure ventilation significantly increases clinical failure odds with an aOR of 3.00 at P < 0.001.