Respiration
December 1, 2025
1 min readIP Score 9/10
Novel Endobronchial Silicone Valve for Treating Lung Emphysema: A Preclinical Trial and First-In-Human Study
Deng M, Zheng Z, Tong R, et al.
Abstract
Introduction: Available endobronchial valves (EBVs) for lung volume reduction in severe emphysema are limited in variety and predominantly feature complex metal-silicone designs (e.g., Zephyr®). This study aimed to introduce a novel, all-silicone endobronchial valve (ESV) designed to simplify manufacturing and potentially improve biocompatibility.
Methods: A preclinical study implanted ESVs or Zephyr® EBVs (1:1) into unilateral caudal lobes of 8 pigs, assessed using computed tomography, bronchoscopy, and necropsy over 6 weeks. A first-in-human (FIH) trial enrolled 3 severe emphysema patients (male, aged 48-72 years, collateral ventilation-negative). ESVs were placed using a bronchoscope under general anaesthesia. Outcomes included procedural success, safety, target lobar volume reduction, lung function, quality of life, and exercise capacity at baseline and 3 and 6 months.
Results: Preclinically, all valves (12 ESV, 12 Zephyr®) were successfully implanted and removed. Complete target lobe atelectasis occurred by 6 weeks in all animals, without major adverse events; localised granulation was observed. In the FIH trial, all ESVs were successfully deployed (procedure time: 5-20 min). Target lobar volume reductions occurred at 6 months in 2 of 3 cases (Case 1: 1.5 L, Case 2: 0.4 L). Emphysema volume decreased at 3 and 6 months. Lung function, quality of life, and exercise capacity showed trends toward improvement. One patient experienced an acute exacerbation of chronic obstructive pulmonary disease; no pneumothorax, pneumonia, or haemoptysis occurred.
Conclusion: Overall, ESV was shown to have an initial feasibility for endobronchial lung volume reduction in humans. Further studies are needed to evaluate the sustained effects.
This case highlights the diagnostic and management challenges of refractory multisystem sarcoidosis progressing over a two-year period despite advanced biologic therapy.
Clinicians should note that the presence of targetable mutations in non-small cell lung cancer with malignant pleural disease is not associated with improved survival, based on the findings from this study.
Shape-sensing robotic-assisted bronchoscopy achieved a strict diagnostic yield of 70.2% with a low pneumothorax rate of 3.3%, demonstrating that earlier tissue diagnosis of very small pulmonary nodules is feasible and safe for clinical practice.
Up nextJournal of Thoracic DiseaseOct 30, 2026Read
This study introduces ultrasound-guided trans-cannula cryobiopsy of supraclavicular lymph nodes as a novel superficial lymph node approach for tissue acquisition in 10 consecutive patients, though specific numeric success or safety results were not provided in the abstract.
Active infection is not an absolute contraindication to endobronchial valve placement, but positive pressure ventilation significantly increases clinical failure odds with an aOR of 3.00 at P < 0.001.