Journal of bronchology & interventional pulmonology
October 1, 2026
1 min readIP Score 10/10
Navigation Bronchoscopy Specific Cone-Beam CT Software Enabling Pre- And Intraprocedural Guidance: A Prospective Clinical Feasibility Study.
Wijma IN; van der Sterren W; Verhoeven RLJ; van der Heijden EHFM
Abstract
BACKGROUND: Cone-beam computed tomography (CBCT)- guided bronchoscopy is an established technique for diagnosing peripheral pulmonary lesions, offering 3-dimensional imaging for both navigation and confirmation. However, its usability as a stand-alone modality is limited by a substantial learning curve and a lack of integrated planning tools. This study evaluates the feasibility and performance of navigation bronchoscopy-specific CBCT software that enables preprocedural CT-planning fusion with intraprocedural CBCT imaging and provides intraprocedural support algorithms. METHODS: This prospective, single-center clinical feasibility study exploratively assessed the usability of the AirWaze investigational software. Usability was measured using a standardized system usability score, with scores of 70 or higher considered indicative of good usability (range, 0-100). The performance of the individual software components ('planning,' 'image fusion,' and 'guidance') was evaluated. An ultralow-dose CBCT protocol was compared with conventional CBCT scans for accuracy and radiation exposure. RESULTS: The study enrolled 34 patients with 37 lesions. The investigational software achieved a system usability score of 45. The planning component was available in all cases and was unanimously rated by the endoscopists as accurate and intuitive. In contrast, the image fusion and guidance components were rated as insufficient. The ultralow-dose CBCT protocol provided clinically accurate imaging in 84% of cases and reduced the radiation dose by 94%. CONCLUSION: Integrating planning and procedural guidance within stand-alone CBCT-guided navigation bronchoscopy procedures has great potential. Although several components of the investigational software were considered valuable, further development is required to ensure comprehensive procedural guidance.
This case highlights the diagnostic and management challenges of refractory multisystem sarcoidosis progressing over a two-year period despite advanced biologic therapy.
Clinicians should note that the presence of targetable mutations in non-small cell lung cancer with malignant pleural disease is not associated with improved survival, based on the findings from this study.
Shape-sensing robotic-assisted bronchoscopy achieved a strict diagnostic yield of 70.2% with a low pneumothorax rate of 3.3%, demonstrating that earlier tissue diagnosis of very small pulmonary nodules is feasible and safe for clinical practice.
Up nextJournal of Thoracic DiseaseOct 30, 2026Read
This study introduces ultrasound-guided trans-cannula cryobiopsy of supraclavicular lymph nodes as a novel superficial lymph node approach for tissue acquisition in 10 consecutive patients, though specific numeric success or safety results were not provided in the abstract.
Active infection is not an absolute contraindication to endobronchial valve placement, but positive pressure ventilation significantly increases clinical failure odds with an aOR of 3.00 at P < 0.001.