Respiration_Online
November 8, 2023
1 min readIP Score 10/10
Impact of Endobronchial Valve Treatment on Lung Function Decline
Abstract
AbstractIntroduction: Endobronchial valve (EBV) treatment has been shown to be beneficial for patients with severe emphysema. The forced expiratory volume in 1 s (FEV1) was found to be significantly higher compared to baseline for up to 3 years after treatment although the magnitude of improvement gradually decreases over time. So far, it has not been investigated whether this treatment decelerates the decline in lung function. Therefore, our aim was to investigate the lung function decline before and after EBV treatment. Methods: We included patients who were treated with EBVs in our hospital, of whom pre-treatment spirometry results were available (at least 4 measurements within at least 2 years before treatment) and who had an annual FEV1 measurement up to 3 years after treatment. Results: In total, 45 patients were included (73% female, FEV1: 28 ± 7% of predicted, residual volume: 232 ± 32% of predicted) who had a mean pre-treatment FEV1 decline of −64 mL/year. Mean FEV1 “decline” after treatment was +13 mL/year, since FEV1 was still above the baseline level at 3-year follow-up. However, the FEV1 decline between 1 and 3 years of follow-up was not significantly different compared to the pre-treatment decline (−73 mL/year, p = 0.179). Conclusions: Our results show that the EBV treatment does not influence the progression of disease in terms of lung function decline. However, the treatment does improve the FEV1 up to a level that is still comparable 3 years after treatment with the baseline level.
This case highlights the diagnostic and management challenges of refractory multisystem sarcoidosis progressing over a two-year period despite advanced biologic therapy.
Clinicians should note that the presence of targetable mutations in non-small cell lung cancer with malignant pleural disease is not associated with improved survival, based on the findings from this study.
Shape-sensing robotic-assisted bronchoscopy achieved a strict diagnostic yield of 70.2% with a low pneumothorax rate of 3.3%, demonstrating that earlier tissue diagnosis of very small pulmonary nodules is feasible and safe for clinical practice.
Up nextJournal of Thoracic DiseaseOct 30, 2026Read
This study introduces ultrasound-guided trans-cannula cryobiopsy of supraclavicular lymph nodes as a novel superficial lymph node approach for tissue acquisition in 10 consecutive patients, though specific numeric success or safety results were not provided in the abstract.
Active infection is not an absolute contraindication to endobronchial valve placement, but positive pressure ventilation significantly increases clinical failure odds with an aOR of 3.00 at P < 0.001.