Cutting waste in bronchoscopy - a multicenter observational study in the German healthcare system.
Seeger A; Welsch L; Kim S; Antonow G; Zeuzem S; Hessz D
Abstract
INTRODUCTION: Pulmonary endoscopy contributes substantially to medical waste generation. Previous studies have estimated the average waste per bronchoscopy at approximately 1.03 kg. However, scalable data are lacking. RESEARCH QUESTION: How much waste is generated by pulmonary procedures with reusable endoscopes (bronchoscopy and endobronchial ultrasound (EBUS)) at two German tertiary care centers, what is the estimated national impact, and which strategies can be identified for waste reduction? STUDY DESIGN AND METHODS: In a prospective, multicenter observational study conducted over four weeks per center, waste from 107 procedures in 79 patients was collected, categorized, and weighed. The proportion of recyclable materials was determined. National waste production was extrapolated using health insurance data. RESULTS: On average, 1479.7 g of waste were generated per patient. Standalone bronchoscopy produced 1276.5 g, while combined bronchoscopy plus EBUS generated 1849.7 g of waste. Extrapolated for Germany's pulmonary endoscopies, this corresponds to 551.6 tons of waste per year, equivalent to 270 tons of COemissions. Of the total waste, 74.8% originated in the examination room, 7.8% from suction bags, and 17.4% from reprocessing and recovery areas. With regard to waste reduction, the use of reusable gowns as personal protective equipment could lead to a 61.5% reduction (p < 0.001). Overall, 28.7% of the waste was potentially recyclable. Using single-use endoscopes instead might have increased the waste per procedure, even though reprocessing waste would have been minimized. An additional 111.8 g of residual waste (+16.0%), 15.1 g of paper (+13.0%), and 1.1 g of plastic (+0.5%) would have been produced per procedure. INTERPRETATION: Pulmonary endoscopies generate considerable amounts of waste. Strategies such as procedural bundling, reusable protective equipment, and recycling can reduce the environmental footprint, whereas the use of disposable bronchoscopes further increases the waste burden.
This case highlights the diagnostic and management challenges of refractory multisystem sarcoidosis progressing over a two-year period despite advanced biologic therapy.
Clinicians should note that the presence of targetable mutations in non-small cell lung cancer with malignant pleural disease is not associated with improved survival, based on the findings from this study.
Shape-sensing robotic-assisted bronchoscopy achieved a strict diagnostic yield of 70.2% with a low pneumothorax rate of 3.3%, demonstrating that earlier tissue diagnosis of very small pulmonary nodules is feasible and safe for clinical practice.
Up nextJournal of Thoracic DiseaseOct 30, 2026Read
This study introduces ultrasound-guided trans-cannula cryobiopsy of supraclavicular lymph nodes as a novel superficial lymph node approach for tissue acquisition in 10 consecutive patients, though specific numeric success or safety results were not provided in the abstract.
Active infection is not an absolute contraindication to endobronchial valve placement, but positive pressure ventilation significantly increases clinical failure odds with an aOR of 3.00 at P < 0.001.