Journal of bronchology & interventional pulmonology
July 1, 2026
1 min readIP Score 10/10
Ambient Sound Pressure Levels in the Bronchoscopy Suite: Contrasting Flexible, Rigid, and Robotic-Assisted Bronchoscopy.
Rakočević R; Dwyer C; Ho KS; Reed RM; Lazo KG; Ashok S
Abstract
BACKGROUND: Operating room noise can result in provider- and patient-related adverse outcomes. The recommended sound pressure threshold in medical settings is 35-45 dB(A). This study aimed to quantify sound pressure across different types of bronchoscopy procedures. METHODS: Sound meters were placed in the bronchoscopy suite. Ambient sound pressure levels were measured continuously during flexible, rigid, and robotic bronchoscopy procedures. Procedures were classified as "quiet" or "loud" using the median equivalent continuous sound pressure level (Leq). A logistic regression model was used to identify associations between the type of bronchoscopy and "loud" or "quiet" procedures. RESULTS: A total of 186 procedures were analyzed, of which 64% were flexible, 11% were rigid, and 25% were robotic. Across all procedures, the median Leq was 56.8 (55.1 to 58.1) dB(A). Leq was 58.2 (57.5 to 58.9), 59.4 (58.6 to 60.5), and 57.9 (57.5 to 58.4) dB(A) for flexible, rigid, and robotic bronchoscopy, respectively (P<0.0001). In comparison to flexible bronchoscopy, rigid bronchoscopy was more likely to be loud, while robotic bronchoscopy was less likely to be loud. CONCLUSION: This is the first study to quantify sound pressure levels during bronchoscopy procedures. Across all types of bronchoscopy procedures, sound pressure levels exceeded those recommended by guidelines for the medical setting and were considered a moderate degree of noise. Rigid bronchoscopy was associated with higher sound pressure levels, whereas robotic-assisted bronchoscopy was associated with lower sound pressure levels when compared with flexible bronchoscopy. Future studies are needed to explore the potential deleterious effects of bronchoscopy noise on operators and patients to inform preventive measures.
This case highlights the diagnostic and management challenges of refractory multisystem sarcoidosis progressing over a two-year period despite advanced biologic therapy.
Clinicians should note that the presence of targetable mutations in non-small cell lung cancer with malignant pleural disease is not associated with improved survival, based on the findings from this study.
Shape-sensing robotic-assisted bronchoscopy achieved a strict diagnostic yield of 70.2% with a low pneumothorax rate of 3.3%, demonstrating that earlier tissue diagnosis of very small pulmonary nodules is feasible and safe for clinical practice.
Up nextJournal of Thoracic DiseaseOct 30, 2026Read
This study introduces ultrasound-guided trans-cannula cryobiopsy of supraclavicular lymph nodes as a novel superficial lymph node approach for tissue acquisition in 10 consecutive patients, though specific numeric success or safety results were not provided in the abstract.
Active infection is not an absolute contraindication to endobronchial valve placement, but positive pressure ventilation significantly increases clinical failure odds with an aOR of 3.00 at P < 0.001.