A Comparative Study of Radiation Exposure in Conventional and Robotic Bronchoscopy.
Ravikumar N; Ho E; Ajmani G; Kaushik N; Dhiman A; Dillingham K
Abstract
BACKGROUND: It remains unclear whether radiation exposure to bronchoscopists and staff differs between conventional and robotic bronchoscopy (RAB). RESEARCH QUESTION: Does the radiation dose received by the bronchoscopist and team members differ between fluoroscopically guided conventional bronchoscopy and RAB? STUDY DESIGN AND METHODS: This prospective study evaluated radiation exposure during conventional and RAB with fluoroscopy. Radiation dose was measured per the International Commission on Radiological Protection (ICRP) and National Council on Radiation Protection and Measurements (NCRP) guidelines. RESULTS: Over a 10-month period, 54 fluoroscopy-guided bronchoscopies were analyzed: 15 conventional and 39 RABs. Among the RABs, 27 used C-arm-based tomosynthesis (CABT) and 12 used standard C-arm fluoroscopy (CF). The median total radiation exposure per case was highest for RAB using CABT (0.237 mSv vs 0.065 mSv vs 0.02 mSv) compared with conventional and RAB with CF, respectively (p=0.025). The comparison of radiation exposure per case between conventional bronchoscopy and RAB with CF showed no difference (p=0.33). RAB with CABT resulted in significantly higher radiation exposure to the operator's skin underneath the thyroid collar (median 0.0022 mSv/min, p=0.007), while both conventional and RAB with CF had negligible exposure at this site (0 mSv/min, p=0.18). Radiation dose to staff (nurses, bronchoscopy technicians, pathologists, and anesthesiologists) was minimal across all procedure types. Patients with BMI >35 had significantly higher Dose-Area Product (DAP) /min (5.1 Gy·cm, p=0.0067), with no differences observed based on nodule size, CT pattern, or location. INTERPRETATION: In this prospective study applying a rigorous methodology to measure and compare radiation doses, we did not find an overall reduction in operator radiation exposure with RAB when only conventional fluoroscopy was used. The addition of CABT was associated with significantly increased radiation dose. The maximum number of RABs using these external imaging modalities performed per year should align with the current regulatory authorities' recommendations.
This case highlights the diagnostic and management challenges of refractory multisystem sarcoidosis progressing over a two-year period despite advanced biologic therapy.
Clinicians should note that the presence of targetable mutations in non-small cell lung cancer with malignant pleural disease is not associated with improved survival, based on the findings from this study.
Shape-sensing robotic-assisted bronchoscopy achieved a strict diagnostic yield of 70.2% with a low pneumothorax rate of 3.3%, demonstrating that earlier tissue diagnosis of very small pulmonary nodules is feasible and safe for clinical practice.
Up nextJournal of Thoracic DiseaseOct 30, 2026Read
This study introduces ultrasound-guided trans-cannula cryobiopsy of supraclavicular lymph nodes as a novel superficial lymph node approach for tissue acquisition in 10 consecutive patients, though specific numeric success or safety results were not provided in the abstract.
Active infection is not an absolute contraindication to endobronchial valve placement, but positive pressure ventilation significantly increases clinical failure odds with an aOR of 3.00 at P < 0.001.